2 Pair, 0.5mm², ESCS, Instrumentation Cable (MAS5002ESCS)

APPLICATION

  • Electrical measuring devices to instrument panel
  • Instrument to instrument
  • Electrical sensing devices to control cabinets
  • Control cabinets to supervisory consoles and panels
  • Telemeters to recorders and annunciators

CONSTRUCTION

Stranded tinned copper conductors, V-90-HT PVC insulation, twisted pair, individual and overall foil shield (100% coverage) with tinned copper drain wires, V-90 PVC jacket with rip-cord.

 

Additional information

No. of Conductors

2 Pair

Nominal Area

0.5mm²

Wire Gauge (AWG)

20 AWG

Stranding No./Size

7/0.3

Conductor Type

Tinned Copper

Insulation Type

PVC

Shielding Type

Individual & Overall Foil – ESCS

Jacket Type

Black PVC

O.D. (mm)

8.5

Packs

Cut to length

No. of PairsNominal Area (mm²)Nominal Overall Diameter (mm)Nominal Jacket Thickness (mm)Ship Weight (kg/km)Maser CodeDownload Datasheet
2 Pair0.5 (20AWG)8.10.880MAS5002ESCSDatasheet
1.5 (16AWG)101127MAS5502ESCSDatasheet
4 Pair0.5 (20AWG)9.51131MAS5004ESCSDatasheet
1.5 (16AWG)11.71210MAS5504ESCSDatasheet
6 Pair0.5 (20AWG)111185MAS5006ESCSDatasheet
1.5 (16AWG)14.51.25316MAS5506ESCSDatasheet
8 Pair0.5 (20AWG)12.51234MAS5008ESCSDatasheet
1.5 (16AWG)15.21.25396MAS5508ESCSDatasheet
10 Pair0.5 (20AWG)13.91282MAS5010ESCSDatasheet
1.5 (16AWG)17.81.25488MAS5510ESCSDatasheet
12 Pair0.5 (20AWG)14.41323MAS5012ESCSDatasheet
1.5 (16AWG)18.41.25568MAS5512ESCSDatasheet
16 Pair0.5 (20AWG)16.31.25441MAS5016ESCSDatasheet
1.5 (16AWG)21.21.5759MAS5516ESCSDatasheet
20 Pair0.5 (20AWG)17.71.25527MAS5020ESCSDatasheet
1.5 (16AWG)22.61.5920MAS5520ESCSDatasheet
24 Pair0.5 (20AWG)20.51.5632MAS5024ESCSDatasheet
1.5 (16AWG)26.51.51108MAS5524ESCSDatasheet

Physical Characteristics0.5mm²1.5mm²
AWG20 AWG16 AWG
Conductor Stranding7/0.307/0.50
Nominal Conductor Diameter (mm)0.91.5
Nominal Insulation Thickness (mm)0.40.4
Nominal Insulation Diameter (mm)1.72.3
Nominal Screen Thickness (mm)0.0250.025
Drain Wire Stranding7/0.27/0.2
Colour CodeBlack and white.
Each pair is numbered.
Black and white.
Each pair is numbered.
Electrical Characteristics0.5mm²1.5mm²
Conductor Resistance at 20°C each wire (Ohm/100m)3.841.36
Nominal Voltage Rating (a.c/d.c)110/150110/150
Maximum Current Rating (Amperes)313
Nominal Capacitance cond to cond Unscreened (nF/100m)8.511
Nominal Capacitance cond to cond Screened (nF/100m)14.520
Nominal Capacitance both wires cond to screen
Screened (nF/100m)2430
Nominal L/R ratio at 1000Hz (μH/Ohm)15.730
Nominal induction at 1000Hz (μH/100m)11095
Nominal characteristic impedance at 1000Hz Unscreened (Ohm)450350
Nominal characteristic impedance at 1000Hz Screened (Ohm)350260
Nominal crosstalk attenuation between pairs @1000 Hz Unscreened (dB/100M)100-
Nominal crosstalk attenuation between pairs @1000 Hz Screened (dB/100M)125-
Nominal Attenuation @1000 Hz between 600 Ohm Terminations Unscreened (dB/100M)0.090.07
Nominal Attenuation @1000 Hz between 600 Ohm Terminations Screened (dB/100M)0.110.09
STANDARDS: AS/NZS 1125, AS/NZS 3808, AS/NZS 60079.14, IEC 60332-1, IEC 60332-3-22 CatA
TESTING: Insulation integrity verified by spark test at 6 KVAC. H.V. Test on cable: Between conductors and conductors to screen at 2kV a.c. for 1 minute. Flame Retardant to IEC 60332-1, IEC 60332-3A.
Available in Standard Black PVC or Intrinsically Safe Blue PVC

http://www.goactive.net.nz/find-your-nearest-electrical-supplier/http://www.advanceelectrical.co.nz/store-locations.htmlhttps://www.corys.co.nz/about/findhttp://www.ideal.co.nz/contact/brancheshttp://www.iesltd.co.nz/contact.htmlhttp://www.jarussell.co.nz/find-a-branchhttp://www.jarussell.co.nz/find-a-branchhttp://www.redpaths.co.nz/about-us/branch-locations/http://www.scottelectrical.co.nz/find-us.htmlhttp://www.telfers.co.nz/